Gardner Bender Gdt-11 User Manual
3 function, 11 range digital multi-meter, Multímetro digital de 3 funciounes, 11 rangos, Gdt-311
Gb instruments multimeter gdt 11 manual - free pdf ebook User manual GB INSTRUMENTS GDT 11 your questions on the GB INSTRUMENTS GDT-11 in the user manual gb multimeter gdt 293a manual PDF Download. Download gb multimeter gdt 293a manual PDF Manual and auto ranging styles. Easy to read digital displays. Gb gdt-11 manual GB Instruments GDT-11. Need user manual for GB GMT-19P Manual for a gardner bender electrical gdt-11 Gardner Bender GB GMT-312 12 Range Pocket Multimeter. GB Instruments GMT-12A, gb instruments gdt-11, gdt-11, gb instruments gdt-11 manual, gdt-11 multimeter manual, gb instruments gdt-11 user manual /pdf/g15m-r-manual-transaxle-disassembly.pdf 2014-11-11. Manual For Gb Instruments Gdt-11 Read/Download. Avr Battery Load Tester Gb Instruments Gdt 11 Gb. L need user manual for GB GMT-19P Gardner Bender/ Posted on Need a gb instruments gmt 19a manual Manual for a gardner bender electrical gdt-11. Calculators pdf texas instruments ti 84 manual texas. Jun 07, 2015 gdt-11 digital multimeter manual. Gb instruments gmt-18a user manualgardner bender multimeter gdt-3190 manual. Gardner bender gdt-3190 continuity test. Gardner bender gdt-3190 battery replacement. Gardner bender multimeter battery replacement. Instruction manual for gb instruments gdt 11. Gb gardner bender gdt 3190 14 range 4 function manual. The GDT-11 is a type of multimeter or voltage tester that is manufactured by Gardner Bender. This is a tool that is used to determine the voltage of an electrical current. This includes determining the voltage of your car's battery and the voltage of the electrical current at an electrical socket. Gardner Bender Gdt 11 Manual - Lib a6280c Spend your time for couple of minutes to see Gardner Bender Gdt 11 Manual. Reading a book won't ever decrease and waste your time to be useless. Reading, for a few people become a need that is to do every day like spending time for eating. But what about you? Would you like to read a publication?
V11A
1.0 METER FUNCTIONS
The 14 position manual ranging smooth rotary dial helps achieve precise and accurate readings and the low battery indicator gives a warning when the batteries need to be replaced. Gardner Bender 4-Function Digital Multimeter - GDT-3190. Gardner Bender 4-Function Digital Multimeter - GDT-3190. DIGITAL MULTI-TESTER. Item # 563269.
3.1 AC Volts
There are two ranges for measuring AC voltage: 200 V and 500 V. For more accurate measurements under 200 volts, use
the 200 Volt setting.
1. Connect the black test lead to the “COM” terminal and the red test lead to the “V/
Ω” input terminal.
2. Set the function/range switch to the appropriate AC V range shown above.
3. Touch the test leads to the circuit under test.
4. Read the value of the measurement displayed.
5. Typical AC Voltage measurements include wall outlets, appliance outlets, motors, light fixtures and switches.When
measuring outlets the specially spaced lead holders allow for single one hand testing
3.2 DC Volts
There are four ranges for measuring DC voltage: 2000m V, 20V, 200 V, and 600 V. For more accurate measurements,
use the lowest range possible without exceeding the value.
1. Connect the black test lead to the “COM” terminal and red the test lead to the “V/
Ω” input terminal.
2. Set the function/range switch to the appropriate DC V range shown above.
3. Touch the test leads to the circuit under test.Touch the black (common) test lead to the negative DC source first and
red (positive) test lead to the “live”source second.
4. Read the value of the measurement displayed.If the leads are reversed a “-“ indicator will appear on the display.
5. Typical DC Voltage measurements include car batteries, automotive switches and household batteries.
3.3 Resistance
There are five ranges for measuring resistance 200, 2000, 20K, 200K and 2 Meg Ohms. For more accurate
measurements use the lowest range possible without exceeding the value.
When measuring resistance always make sure the power is off.
1. Connect the black test lead to the “COM” terminal and red the test lead to the “V/
Ω” input terminal.
2. Set the function/range switch to the appropriate resistance (ohms) range shown above.
3. Touch the test leads to the resistor or non-energized component to be measured. Use the 2000K range when testing
for resistance values in electronic components such as resistors and potentiometer. If the value of the component falls
within the range of another setting, reset the function/range switch to that setting for a more accurate reading.
4. Read the value of the measurement displayed. With resistance measurements, the polarity of the test leads is
not a factor.
5. Typical resistance/continuity measurements include resistors, potentiometer, switches, extension cords and fuses.
4. Battery Replacement
Note: When the battery’s voltage drops below the operating voltage, the mark “ ” will appear on the LCD. Please
replace the battery.
Caution: When changing the battery, disconnect the test leads from the circuit completely.
1. Remove the screws in the back cover of the tester and carefully separate the back cover from the front.
2. Remove the battery from the contacts, noting the polarity of the battery terminals and contacts.
3. Replace with one fresh 9 volt battery.
Note: Do not use rechargeable or lithium batteries in this unit.
4. Carefully replace the back cover and tighten the screws. Do not overtighten the screws as this may strip the threads
in the tester housing.
!
WARNING
WARNING
Contents
1.
Meter Functions
2.
Read First
2.1
For Your Safety
3.
Operating Suggestions
3.1
AC Volts
3.2
DC Volts
3.3
Resistance
4.
Battery Replacement
3 Function, 11 Range
Digital Multi-Meter
Owners Manual
• Read this owners manual thoroughly
before use and save
Milwaukee, WI 53209
1.800.822.9220
www.gardnerbender.com
ZX401 Rev. B
GDT-311
V11A
Multímetro digital de 3
funciounes, 11 rangos
Manual del propietario
• Lea completamente este manual del
propietario antes del uso y consérvelo
para referencia futura.
GDT-311
Especificaciones del medidor
tipo de medidor
manual
funciones:
3
rangos:
11
Cuenta en pantalla:
2000
impedancia de entrada:
10 Meg Ohmios
Rangos de voltios de CA: 200 / 500 (2.5% + 5 dígitos)
Rangos de voltios de CC: 2 / 20 / 200 / 600 (1.2%+2 dígitos)
Rangos de resistencia:
200 / 2k / 20k / 200k / 2M
(1.5% + 2 dígitos)
Condiciones ambientales
Uso interior
Temperatura de servicio:
0°C – 40°C
Temperatura de
almacenamiento:
-10°C – 50°C
Humedad Relativa:
0% – 75%RH (0°C – 31°C)
0% – 50%RH (31°C – 40°C)
Altitud:
hasta 2000m
Grado de protección del ingreso:
IP20
Grado de contaminación:
2
2.0 LEER PRIMERO:
Lea este manual del operador completamente antes de utilizar este multímetro. El fin de este manual es
proporcionar información básica relacionada con este multímetro y describir procedimientos básicos de
prueba que pueden realizarse con este probador. La medición de muchos tipos de aparatos, maquinaria
y otros circuitos eléctricos no se menciona en este manual y debe solicitarse la asesoría de técnicos de
servicio experimentados.
La marca “ ” sobre el equipo representa precaución, riesgo de descargo eléctrica.
La marca “ ” sobre el equipo representa precaución, riesgo de peligro.
La marca “ ” sobre el equipo representa el terminal de tierrar funcional.
La marca “ ” sobre el equipo representa el equipo protegido totalmente por AISLAMIENTO DOBLE o
AISLAMIENTO REFORZADO.
PRECAUCION SEA SUMAMENTE PRECAVIDO CUANDO USE ESTE MULTÍMETRO. EL USO
INDEBIDODE ESTE PROBADOR PUEDE PROVOCAR GRAVES DAÑOS MATERIALES Y LESIONES PERSONALES
GRAVES O FATALES. SIGA TODAS LAS INSTRUCCIONES Y SUGERENCIAS DE ESTE MANUAL DEL OPERADOR
Y OBSERVE ADEMAS LAS PRECAUCIONES NORMALES DE SEGURIDAD ELECTRICA. NO UTILICE ESTE
MULTIMETRO SI NO TIENE EXPERIENCIA EN CIRCUITOS ELECTRICOS Y DESCONOCE LOS PROCEDIMIENTOS
CORRECTOS DE PRUEBA.
2.1 Para su seguridad
1) Sea sumamente precavido cuando revise circuitos eléctricos.
2) Aléjese de las áreas mojadas o húmedas cuando trabaje con electricidad. Use botas o zapatos con
suelas de goma.
!
ADVERTENCIA
ADVERTENCIA
!
ADVERTENCIA
ADVERTENCIA
1. 3-1/2 Digit LCD
Display
Pantalla de cristal líquido
de 3-1/2 dígitos
Affichage numérique
3-1/2 po
2. 11 Position
Dial giratorio suave de 11
posiciones/rangos
Sélecteur de
fonction/plage 11
positions
3. AC Volts
Voltios de CA
Volts c.a.
4. DC Volts
Voltios de CC
Volts c.c.
5. Resistance
Resistencia
Résistance
6. On/Off Button
Botón de encendido
y apagado
Bouton Marche/Arrêt
7. Low Battery Indicator
Indicador de batería
baja
Indicateur de pile faible
8. Common Input Jack
Toma de entrada
común
Prise d'entrée
commune
9. Positive Input Jack
Toma de entrada
positiva
Prise d'entrée positive
Meter Type:
manual
Functions:
3
Ranges:
11
Display Count:
2000
Input Impedance:
10 Meg Ohm
AC Volt Ranges:
200 / 500 (2.5% + 5 digits)
DC Volt Ranges:
2000m V / 20V / 200V / 600V (1.2% + 2 digits)
Resistance Ranges:
200 / 2k / 20k / 200k / 2M
Ω (1.5% + 2 digit)
Operating Environment
Indoor Use
Operating Temperature:
The Behringer Eurodesk SX2442FX-PRO 24-Channel Audio Console is an affordable audio mixer that delivers a feature set suitable for recording and live sound applications. The desk features a total of 24 input channels, with 16 mono and 4 stereo input channels. All mono inputs include XLR microphone inputs and inserts for routing signal to external processors.The mixer's recording features include a built-in 24-bit VIRTUALIZER effects processor, 4-band EQ section and 4-bus outputs for routing to monitors, multi-track recorders, etc.
0°C – 40°C
Storage Temperature:
-10°C – 50°C
Relative Humidity:
0% – 75%RH (0°C – 31°C)
0% – 50%RH (31°C – 40°C)
Altitude:
Up to 2000m
Ingress protection degree: IP20
Pollution degree:
2
Battery Type:
9 Volt
Battery Life:
100 hours with carbon-zinc cells, 200 hours with
alkaline cells under normal conditions.
Overrange Indication:
The three least significant digits are blank and
the number “1” is displayed at the left when the
range capacity is exceeded by the input.
Polarity Indication:
“-” is displayed for negative polarity
Size (LxWxH):
139.2mm x 82.8mm x 30.3mm (includes
rubber boot)
Weight:
Approximately 170g (includes battery)
Test lead type:
ETL, cETL, CE, CAT III 600V 1A
Agency Approvals:
ETL, CE, CAT III 600V
Note: Accuracy is given for one year at 23°C ± 3°C rH<70%
The marking “ ” on the equipment represents Caution, risk of electric shock.
The marking “ ” on the equipment represents Caution, risk of danger.
The marking “ ” on the equipment represents Functional earth terminal.
The marking “ ” on the equipment represents Equipment protected by DOUBLE INSULATION or
REINFORCED INSULATION.
Use extreme cau
t
ion when using this multimeter. Improper use of this meter can result in severe damage to
property, severe personal injury or death. Follow all instructions and suggestions in this operators manual as
well as observing normal electrical safety precautions. Do not use this meter if you are unfamiliar with
electrical circuits and proper test procedures.
2.1 For Your Safety
1)
Use extreme caution when checking electrical circuits.
2) Do not stand in wet or damp work areas when working with electricity. Wear rubber soled boots or shoes.
3) Do not apply more voltage or current than the set range of the multimeter will allow
4) Do not touch the metal probes of the test leads when making a measurement.
5) Replace worn test leads. Do not use test leads with broken or tattered insulation. Only test leads meeting
ETL, cETL, CE, CATIII 600V 1A can be used in this unit.
6) Discharge a capacitor before measuring it.
7) Remove the test leads from the circuit being measured as soon as the test is completed. Never reset the
function/range switch to another range while the leads are still in contact with a circuit.
8) Do not measure voltage when the function/range switch is set on the resistance (ohms) setting. Do not measure
current when the meter is set on the resistance range. Never measure AC voltage when the meter is set on DC
voltage. Setting the meter on the incorrect function may burn out some of the internal circuitry and may pose a
safety hazard.
9) Damaged meters are not repairable nor is calibration possible. Damaged meters should be
disposed of.
3.0 Operating Suggestions
1) Set the function/range switch to the proper position before making a measurement. When the voltage is not known, it
MUST be determined that the capacity of the selected range will handle the amount of voltage or current in the circuit
(See #3 under “For Your Safety”).
2) Avoid placing the meter in areas where vibration, dust or dirt are present. Do not store the meter in excessively hot,
humid or damp places. This meter is a sensitive measuring device and should be treated with the same regard as
other electrical and electronic devices.
3) When the meter is not in use, keep the meter turned to keep the battery from discharging.
4) When disconnecting the test leads from the unit, always grasp the leads where the input jacks meet the tester
housing. Do not pull the leads out of the jacks by the insulated wire or transport the tester using the test leads as a
carrying strap.
5)
Do not immerse the meter in water or solvents. To clean the housing use a damp cloth with a minimal
amount of mild soap.
NOTE: With any measurement made by this meter, there will be some fluctuation of the digital display. This is
due to the meter’s sampling method. This unit samples at a rate of 2 times per second, thus the fluctuation of
the readout.
!
WARNING
WARNING
!
WARNING
WARNING
!
WARNING
WARNING
!
WARNING
WARNING
!
WARNING
WARNING
1
3
5
9
8
6
7
DC Volts
AC Volts
Resistance
2
4
2.0 READ FIRST: IMPORTANT SAFETY INFORMATION
Read this operators manual thoroughly before using this multimeter. This manual is intended to provide
basic information regarding this meter and to describe common test procedures which can be made with
this unit. Many types of appliance, machinery, and other electrical circuit measurements are not
addressed in this manual and should be handled by experienced service technicians.
!
Dial Settings
Contenido
1.0
Funciones del probador
2.0
Leer Primero
2.1

Para su seguridad
3.0
Instrucciones operativas
3.1
Voltios de CA
3.2
Voltios de CC
3.3
Resistencia
4.0
Reemplazo de la bateria
tipo de batería:
9 voltios
Duración de la batería:
100 horas con pilas de carbono-cinc,
200 horas con pilas alcalinas bajo
condiciones normales.
Indicación sobre rango:
Los tres dígitos menos significativos están
en blanco y aparece el número “1” a la
izquierda cuando la entrada supera la
capacidad de rango.
Indicación de polaridad:
Aparece “-“ para la polaridad negativa
Tamaño (LxWxH):
139.2mm x 82.8mm x 30.3mm
(incluyendo bota de gomma)
Peso:
Aproximadamente 170g
(incluyendo la batería)
Tipo de plomos de prueda: ETL ,cETL , CE ,CATIII 600V 1A
Aprobaciones de agencias: ETL, CE, CAT III 600V
Nota: Exactitud es dada por un año, en 23°C ± 3°C rH<70%
!
3131884
CONFORMS TO UL 61010-1
CERTIFIED TO CAN/CSA-
C22.2 No.61010-1
GDT-311 rB 9-09 manual.qxd 9/3/09 4:40 PM Page 1
2012-07-16 Views:157
The GDT-11 is an entry level multimeter used for basic electronics testing. The GDT-11 is a 5-function, 18-range multimeter. It can be used for testing everything from home electronics to automotive wiring. The GDT-11 is easy to use. However, as easy
The GDT-11 is an entry level multimeter used for basic electronics testing. The GDT-11 is a 5-function, 18-range multimeter. It can be used for testing everything from home electronics to automotive wiring. The GDT-11 is easy to use. However, as easy as it is to operate, learning to use this multimeter can be a daunting task. Use a few basic techniques to become proficient at using the GDT-11 multimeter.
Skill level:Moderately Easy
Things you need
GDT-11 multimeterPhillips screwdriversTest leadsAlligator clips
Instructions
1
Install the batteries. The GDT-11 multimeter uses a single 9-volt battery. To install the batteries, use a Phillips screwdriver to remove the two screws that hold the case's back panel in place. Remove the battery's lead from the battery compartment. Connect the battery and place it back into the compartment. Tighten the mounting screws.
2 Turn the GDT-11 on. The GDT-11 has a single control for all operations. This control is a large dial in the centre of the multimeter's front casing. To turn it on, move the dial to the left or right of the 'Off' position, depending on the testing mode. If testing volts, move the dial to the left and select 1 of the 5 voltage test settings.
3
Determine the range being tested. Refer to either the user manual or manufacturer's website for the electrical value of the component being tested. If testing voltage, determine the voltage load before choosing the testing mode.
4 Choose a testing mode. The GDT-11 can test volts, amps or ohms. Each testing mode is further subdivided to narrow down the testing range. If testing ohms, choose the appropriate ohms setting. The ohms settings are found on the lower left hand side of the dial. Each grouping of test settings is outlined by a white or green border. The ohms settings are surrounded by a green border.
5
Insert the test leads. The GDT-11 comes with two leads, one black and the other red. The black test lead goes into the 'COM' jack. The GDT-11 has two different jacks for the red test lead. One is the '10A DC' jack and the other is the 'V(ohm)ma' jack. The '10A DC' is used for direct current testing. The 'V(ohm)ma' is used when testing volts, ohms and amps. Choose the appropriate jack. If testing for resistance, use the 'V(ohm)ma' jack.
6 Connect the leads to the component being tested. The GDT-11 comes with two test leads. The leads have 1-inch-long metal tips. When testing a component, place the black lead on the negative terminal and the red lead on the positive terminal.
7 Adjust the multimeter's settings. If the reading on the multimeter's digital screen gives a '0' reading, adjust the GDT-11's settings either up or down. The GDT-11 has five voltage settings, five ohm settings and four amp settings. Set the testing mode to either a higher or lower setting based on the component's specifications.
Tips and warnings
Gardner Bender Gdt-11 Manual
Use alligator clips to hold the leads to the component being tested.