Back-UPS ES 350/500

The Back-UPS ES is operating normally. The Back-UPS ES can only operate on battery power for a limited amount of time. The unit will eventually turn off when the available battery power has been used. Allow the unit to recharge for 16 hours before expecting maximum runtime. The output waveform is designed for computers and computer-related.

APC Back-UPS® 300, 500, 650 User’s Manual 990-2004E Revision 7 12/99 Inspect Inspect the UPS and its contents on receipt:. User’s Manual. Cord straps (2)UPS. Telephone cable. Warranty card. APC Solutions magazine. Equipment Protection policy 500 and 650 VA models:. PowerChute® plus software CD. Interface cable. Software Install Sheet. Jan 26, 2012  My 4 year 2 month old APC Back-UPS ES 750 using Powerchute 2.0 Firmware revision: 841.I2.D will only charge to 98% and after being on for about 30 mins goes down to 91% and always says charging (see attached). Windows 7 Home Premium. I have un/reinstalled the software but I did not let the battery run down. RefurbUPS APC Back-UPS ES 750 G (BE750G) High Capacity 9 Amp Battery Replacement Kit. 5.0 out of 5 stars 1. $11.07 shipping. Amazon's Choice for apc back-ups es 750. APC UPS Battery Replacement for APC UPS Models BE650G1, BE750G, BR700G, BE850M2, BX850M, BE650G, BN600, BN700MC, BN900M, and select others (RBC17). Jan 29, 2018  APC Back-UPS BX - Uninterruptible Power Supply 700VA, - BX700UI - AVR, 4 Outlets IEC-C13, USB, Shutdown Software Back-UPS BX provides guaranteed power.

User’s Guide

1

2

3

Connect Battery

Connect
Equipment

Power On and
Install Software

990-9197 Revision 1 11/01 Copyright © 2001 American Power Conversion Corp.

All other trademarks are property of their respective owners.

The Back-UPS ES is shipped with one battery wire disconnected in compliance with Department of Transportation (DOT) regulations. The Back-UPS ES
will not operate until the wire is connected to the touch safe battery terminal.

NOTE: Small sparks may occur during battery connection. This is normal.

1

2

4

TURN the Back-UPS ES over and
remove the battery compartment
cover screw using a flat blade or
phillips-head screwdriver.

Slide the battery
compartment cover
completely off of
the Back-UPS ES.

Replace the battery,
battery compartment
cover and cover
retaining screw.

Surge Protection

These outlets provide full-time protection from surges even if
the Back-UPS ES is switched OFF. Plug your printer, fax
machine, scanner, or other peripherals that do not need
battery power into these outlets.

Ups

Battery Back-up

plus Surge Protection

These outlets are powered whenever the Back-UPS ES is
switched ON. During a power outage or other utility problems
(brownouts, over-voltages), these outlets will be powered for a
limited time by the Back-UPS ES. Plug your computer, monitor,
and one other data-sensitive device (external disk or tape
drive) into these outlets.

Connect FAX/Modem/Phone

Back-UPS ES protects a single
line (2-wire) fax, modem or
phone from surges when it is
connected through the Back-
UPS ES as shown.

Place the Back-UPS ES to avoid:

- Direct sunlight
- Excessive heat
- Excessive humidity or contact with fluids

Plug the Back-UPS ES power cord directly
into a wall outlet; not a surge protector or
power strip.

Connect Computer Cable

The supplied cable and software provide
automatic file saving and shutdown of the
operating system in the case of a sustained
power outage.

Connect the cable to the Data Port of the Back-
UPS ES. Connect the other end of the cable to
the USB port on your computer. The software will
automatically find the USB Port of your
computer.

Press the ON/OFF switch to power the unit
ON.

A single short beep and the green “Power On”
indicator confirms that Back-UPS ES is on and
ready to provide protection.

The Back-UPS ES should charge for at least
16 hours to ensure sufficient runtime. The unit
is being charged whenever it is connected to
utility power, whether the unit is turned ON or
OFF.

If the red Building Wiring Fault indicator
(located on the end near the power cord) is lit,
your building wiring presents a shock hazard
that should be corrected by a qualified
electrician.

Install the PowerChute Personal

®

Edition

software

Place the PowerChute Personal Edition CD-
ROM into your computer and follow the
installation instructions on the screen.

3

LIFT the battery out of the compartment and connect the
black wire to the battery terminal.

www.apc.com

®

P o w e r O n

Battery Backup

plus Surge Protection

Wall Outlet

Modem/Phone/Fax

Computer

USB Port

Surge Protection

Back-UPS ES 500

Back-UPS ES 350

APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.

The Back-UPS ES indicates operating status using a combination of visual and audible indicators.

Status

Visual Indications

Audible Indication

Alarm Terminates

When

On Line - UPS is supplying conditioned
utility power to the load

Power On LED - ON

None

Enabling these cookies, you help us to offer you a better experience. We can directly use technical cookies, but you have the right to choose whether or not to enable statistical and profiling cookies. On this website we use first or third-party tools that store small files ( cookie) on your device. Janome sewing machine instructions. Cookies are normally used to allow the site to run properly ( technical cookies), to generate navigation usage reports ( statistics cookies) and to suitable advertise our services/products ( profiling cookies).

n/a

On Battery - UPS is supplying battery
power to the load connected to the
Battery outlets

Power On LED - ON
(off during beep)

Beeping 4 times
every 30 seconds

UPS transfers back to
On Line operation, or
when UPS is turned
off.

Low Battery Warning - UPS is supplying
battery power to the load connected to
the Battery outlets and the battery is near
exhuastion

Power On LED -
Flashing

Rapid beeping (one
second intervals)

UPS transfers back to
On Line operation, or
when UPS is turned
off.

Replace Battery - Battery needs to be
checked and/or replaced, or battery is not
connected

Power On LED -
Flashing

Constant tone

UPS turned off with
the power switch.

Overload Shutdown - During On Battery
operation a battery power supplied outlet
overload was detected.

Power On LED - OFF

Apc back ups es 750 manual

Constant tone

UPS turned off with
the power switch.

Sleep Mode - During On Battery
operation the battery power has been
completely exhausted and the UPS is
waiting for utility power to return to
normal.

Power On LED - OFF

Beeping once every
4 seconds

UPS transfers back to
On Line operation, or
when UPS is turned
off.

Building Wiring Fault - Your building
wiring presents a shock hazard that
should be corrected by a licensed
electrician.

Building Wiring Fault
LED (red) - ON

None

UPS is unplugged, or
plugged into a
properly wired outlet.

Status Indications

Power On

Circuit

Breaker

AC Line

Cord

Building Wiring

Fault Indicator

UPS Power

On Indicator

Power

Switch

®

See the Troubleshooting section for additional assistance.

Sold by:

http://www.TWAcomm.com
Toll Free: (877) 892-2666

Advertising
Popular Brands
Popular manuals
Summary of the content on the page No. 1


Installation Guide Smart-UPS X
750/1000/1500 VA Rack-Mount 2U
Important Safety Messages
Read the instructions carefully to become familiar with the equipment before trying to install, operate, service
or maintain it. The following special messages may appear throughout this manual or on the equipment to
warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol to a Caution product safety label indicates that a hazard e

Summary of the content on the page No. 2

Inventory All models (4) (1) (1) (1) (1) (4) (1) (2) (2) (1 pair) (2) (4) Rack-Mount brackets 230 Vac models 750/1000 VA models 1500 VA models (2) (2) (2) (4) (1 pair) Models with preinstalled network cards 2 Installation Smart-UPS X 750/1000/1500 VA 120/230 Vac Rack-Mount 2U gen0744a su0434a

Apc Backup Ups Es 750 Manual

Summary of the content on the page No. 3

su0336a Installation Connect the battery Tower to rack-mount conversion 750/1000 VA Rack-mount to tower conversion 1500 VA 12 3 Two post rack Front mount installation 750/1000 VA 1 2 3 Installation Smart-UPS X 750/1000/1500 VA 120/230 Vac Rack-Mount 2U 3 su0322a su0331a su0320a su0324a su0356a su00335a su0337a su0332

Summary of the content on the page No. 4

Center mount 750/1000/1500 VA 12 Four post rack installation 1500 VA Use the APC Four Post Rail Kit (included with 1500 VA models only.) 12 Install the bezel and rotate the logo 4 Installation Smart-UPS X 750/1000/1500 VA 120/230 Vac Rack-Mount 2U su0357a su0321a su0440a su0323a su0442a

Summary of the content on the page No. 5

Start Up and Configuration Overview 120 Vac SmartSlot 1 External battery pack connector 2 Outlets 3 EPO connector 4 USB port 5 Serial port 6 Chassis ground screw 7 UPS input 8 230 Vac Circuit breaker 9 Controllable outlet groups The outlets on the UPS are configured into groups. To configure the controlled outlet features, navigate to: Main Menu > Control > Outlet1 Control. SKU Controllable Outlet Group 1 750 VA 1000 VA 1 & 2 1500 VA 1, 2, & 3 230 V 1500 VA 120 V 1500 VA Examples of switch

Summary of the content on the page No. 6

Apc Back-ups Es 750 Manual

Electrical connections CAUTION RISK OF EQUIPMENT DAMAGE • Adhere to all local and national electrical codes. • Wiring should be performed by qualified electrician. • Always connect the UPS to a grounded outlet. Failure to follow these instructions can result in equipment damage Display Interface Online LED 1 UPS ON/OFF key 2 On Battery LED 3 Site Wiring Fault LED 4 Replace Battery LED 5 Display interface 6 UP/DOWN arrow keys 7 ENTER key 8 APC by Schneider ESC key 9 Electric su0343a ® Select mod